Hounsfield scale
Introduction
The Hounsfield scale (in English - Hounsfield) — a quantitative scale of X-ray density (radiodensity).
Definition
The scale of Hounsfield units (densitometric values, English HU) — a scale of linear radiation attenuation relative to distilled water, whose X-ray density was taken as 0 HU (at standard pressure and temperature).
For a material X with a linear attenuation coefficient μX , the HU value is determined by the formula
$${\mu_X - \mu_{water} \over \mu_{water} - \mu_{air}} \times 1000 $$
where μwater and μair — the linear attenuation coefficients for water and air under standard conditions.
Thus, one Hounsfield unit corresponds to a 0.1% difference in radiation attenuation between water and air, or approximately 0.1% of the attenuation coefficient of water, since the attenuation coefficient of air is practically zero.
The standards given above were chosen for practical use in computed tomography of living organisms (including humans), since their anatomical structures consist largely of bound water.
Average densitometric values
|
Substance
(Substance) | HU | |
|---|---|---|
| Air | −1000 | |
| Fat | −120 to −90 | |
|
Soft tissues on contrast CT
(Soft tissue on contrast CT) | +100 to +300 | |
| Bone | Cancellous | +300 to +400 |
| Cortical | +1800 to +1900 | |
|
Subdural hematoma
(Subdural hematoma) | First hours | from +75 to +100 |
|
After three days
(After 3 days) | from +65 to +85 | |
| After 10-14 days | from +35 to +40 | |
|
Other blood
(Other blood) |
Unclotted
(Unclotted) | from +13 to +50 |
| Clotted | from +50 to +75 | |
|
Pleural effusion
(Pleural effusion) |
Transudate
(Transudate) | from +2 to +15 |
|
Exudate
(Exudate) | from +4 to +33 | |
|
Other fluids
(Other fluids) | Chyle | −30 |
| Water | 0 | |
| Urine | -5 to +15 | |
|
Bile
| -5 to +15 | |
|
Cerebrospinal fluid (CSF) | 15 | |
|
Abscess / Pus | 0 or +20, up to +40 or +45 | |
| Mucus | 0 - 130 ("high attenuating" at over 70 HU) | |
| Parenchyma | Lung | -700 to −600 |
| Kidney | +20 to +45 | |
| Liver | 60 ± 6 | |
| Lymph nodes | +10 to +20 | |
| Muscle | +35 to +55 | |
| Thymus | +20 to +40 in children | |
| +20 to +120 in adolescents | ||
|
White matter
(White matter) | from +20 to +30 | |
|
Grey matter
(Grey matter) | from +37 to +45 | |
| Gallstone |
Cholesterol stone
(Cholesterol stone) | from +30 to +100 |
|
Bilirubin stone
(Bilirubin stone) | from +90 to +120 | |
|
Foreign body
(Foreign body) |
Windowpane glass
(Windowpane glass) | 500 |
| Aluminum, tarmac, car window glass, bottle glass, and other rocks | +2,100 to +2,300 | |
|
Limestone
Limestone | 2,800 | |
| Copper | 14,000 | |
| Silver | 17,000 | |
| Steel | 20,000 | |
|
Gold, steel and brass
(Gold, steel, and brass) | +30,000 (upper limit of measurements) | |
| Earwax | <0 | |
History
The scale was proposed by Sir Godfrey Newbold Hounsfield, one of the chief engineers and developers of axial computed tomography.
CT scanners became the first devices that made it possible to visualize the anatomy of living beings in three dimensions in detail.
Since the early 1990s, the development of computer technology has made it possible to create 3D reconstruction software.
By comparison, conventional X-ray images show only the projected overlap of complex anatomical structures, that is, their summed X-ray shadow.
Further
If you have read this far, I can recommend my
collection of video lessons about computed tomography
and related topics.
You can watch the videos
here
.
Article author: Andrei Olegovich